Enter layer thickness and thermal conductivity in the stated units. Use conductivity data appropriate to the actual product and conditions.
Let’s calculate.
Usage estimateCalculate thermal resistance of one homogeneous layer.
Formula and worked example
R = thickness / conductivity
Reference example
0.1 m thickness at 0.04 W/(m·K) gives 2.5 m²·K/W.
When this calculation applies
The result is m²·K/W, not the numerical US customary R-value. Conductivity must match the material and conditions. Surface resistances, other layers, thermal bridges and installation defects are excluded.
Background reference: OpenStax. References explain the method or units; they do not certify this calculator.
Source scope: The heat-transfer chapter supports one-dimensional steady conduction. CalcuAll’s single-layer resistance or supplied U-value does not establish whole-building performance or regulatory compliance.
For the derivation, input conventions and numerical limits, open .
How to use this result
A 0.12 m layer with conductivity 0.04 W/(m·K) has R = 3 m²·K/W. Doubling that thickness to 0.24 m gives R = 6 under the same idealized conditions. The result is a layer value, not a whole-wall U-value.
Can I take 1/R as the building U-value?
Not from this layer alone. A whole assembly can include other layers, surface resistances and thermal bridges. The reciprocal of a complete appropriate total resistance is a different calculation from the reciprocal of one insulation layer.
Is this the same number as US R-value?
No. This result uses m²·K/W. US customary area-specific resistance uses different units and has a different numerical value. Do not compare unlabeled R-values from different unit systems.
Does more numerical precision make the estimate more accurate?
No. Moisture, temperature, product variability, compression and installation can affect performance. Displayed decimals cannot substitute for suitable product data or an assessment of the actual construction.