CalcuAll.
A quick calculation, right here.

CalcuAlltor.

FREE ONLINE SCIENTIFIC CALCULATOR

0
Ready when you are.
English

Chemistry

Combined Gas Law — Final Volume

Estimate final gas volume after pressure and temperature changes.

Let’s calculate.

Usage estimate

Estimate final gas volume after pressure and temperature changes.

Your result
—L
Rounded to up to 2 decimal places.

Measurement units

Changing an input unit reinterprets its number. A compatible result unit follows it automatically; you can then choose a different result unit.

EXPLORE THE FORMULA

Combined Gas Law — Final Volume

Chemistry · FORMULA GUIDE

Your current calculation

The values and displayed result follow the calculator as you edit it.

Initial gas volume
—
Initial absolute pressure
—
Initial absolute temperature
—
Final absolute pressure
—
Final absolute temperature
—
Your result—
This panel uses the calculator’s displayed, rounded result.

The formula

V₂ = V₁ × (p₁/p₂) × (T₂/T₁)

Estimate final gas volume after pressure and temperature changes.

Variables and input conventions

v1
Initial gas volume (L)
p1
Initial absolute pressure (Pa)
t1
Initial absolute temperature (K)
p2
Final absolute pressure (Pa)
t2
Final absolute temperature (K)

Understanding the relationship

At fixed amount nR is constant, so p₁V₁/T₁ = p₂V₂/T₂. Leaks, reactions or condensation invalidate the fixed-amount assumption.

Interpreting the chemistry

The same amount of ideal gas must remain between states. Both temperatures are kelvin and both pressures absolute. Leaks, condensation and chemical reactions can invalidate the model. Equal states preserve the initial volume.

A worked example

V₂ = 1 × (100000/200000) × (300/300) = 0.5 L.

A fixed reference example; it does not change with your inputs.

Assumptions and valid inputs

All inputs positive. Fixed gas amount; ideal gas, equilibrium states, absolute pressures and Kelvin temperatures.

Numeric entries accept a decimal point or comma and scientific notation, up to 100 characters, with magnitude from 10⁻¹⁰⁰ to 10¹⁰⁰ or zero. Field-unit selectors convert independently; printed compound units without selectors remain fixed. Gas temperatures use positive absolute kelvin. Half-life calculations support up to 10,000 half-lives for positive initial amounts; Arrhenius calculations support an exponential argument from −10,000 to 10,000. Values outside these computational limits show an error rather than silent underflow.

Rounding and numerical precision

Chemistry calculations use a private 640-significant-digit decimal context. The SI Avogadro and gas constants use their exact defining values, but input measurements and idealised chemical models still have their own uncertainty. Choose 0–8 decimal places for display and copying. Trailing zeros are omitted; very small values may round to zero. Display rounding does not change the underlying calculation. Finite-precision arithmetic is not symbolic exact arithmetic.

Accuracy of input data

Extra displayed decimals do not improve input accuracy. Measurement uncertainty, product variability and uncertain chosen rates are separate from rounding. This tool does not propagate measurement uncertainty. Check that its stated assumptions describe your situation.

Units and dimensions

Input-unit changes reinterpret the entered number. A compatible result unit follows where possible; choose another output unit to convert the answer. Length, area, volume and mass are distinct dimensions. Fixed compound units printed on a field remain part of its definition.

References for unit conventions, not endorsements of every calculator’s model.

References and further study

OpenStax

The chemistry chapter supports the stated chemical quantity or model. Species, concentrations, volumes and constants must match the tool’s conventions; the reference does not supply a preparation procedure or establish experimental accuracy.

Related tools

Formula and worked example

V₂ = V₁ × (p₁/p₂) × (T₂/T₁)

Reference example

V₂ = 1 × (100000/200000) × (300/300) = 0.5 L.

When this calculation applies

The same amount of ideal gas must remain between states. Both temperatures are kelvin and both pressures absolute. Leaks, condensation and chemical reactions can invalidate the model. Equal states preserve the initial volume.

Background reference: OpenStax. References explain the method or units; they do not certify this calculator.

Source scope: The chemistry chapter supports the stated chemical quantity or model. Species, concentrations, volumes and constants must match the tool’s conventions; the reference does not supply a preparation procedure or establish experimental accuracy.

For the derivation, input conventions and numerical limits, open .